RDCU-12C Control Unit Features:
- 3 analog inputs - differential, common mode voltage ±15 V, galvanically isolated as a group, one ±0(2) to 10 V, resolution 12 bit, two 0(4) to 20 mA, resolution 11 bit
- 2 analog outputs - 0(4) to 20 mA, resolution 10 bit
- 7 digital inputs - galvanically isolated as a group (can be split in two groups), Input voltage 24 V DC, Filtering (HW) time 1 ms
- 3 digital (relay) outputs - Changeover contact, 24 V DC or 115/230 V AC, Max. continuous current 2 A
- Reference voltage output: ±10 V ±0.5%, max. 10 mA
- Auxiliary power supply output: +24 V ±10%, max. 250 mA